- Back-UPS®RS 700 Installation & Operation Overview Connect the battery Inventory Safety Do not install the UPS in direct sunlight, in excessive heat, humidity, or in contact with fluids. Do not connect a laser printer or hair dryer to the unit. Ensure that the connected equipment does not exceed the maximum load. Front panel Rear Panel.
- Back-UPS® Models 250, 400, 450, 600, 900 & 1250 User's Manual. Important safety instructions! Thank you for selecting this American Power Conversion Uninterruptible Power Source (UPS). It has been designed for many years of reliable, maintenance free service. American Power Conversion is dedicated to the development of high.
SPECIFICATIONS
May 24, 2012 Thanks Jonathan. I have an RS-900. So I set the sensitivity to low, and that 'fixed' the problem - it didn't immediately flip to battery. Again, my voltage is around 119V - no where near the low or middle limit to cause a switch to battery - that stays on battery.
Item
Specification
On-line Input Voltage Range
(default settings)
83 - 147 Vac (RS model)
83 - 139 Vac (XS model)
Automatic Voltage Regulation (AVR)
+12% (XS model) +12% (RS model)
On-line Frequency Range
47 - 63 Hz (autosensing)
Yamaha dt 175 manual free download. Download Yamaha DT175 DT175D DT 175 92 Service Repair Workshop Manual. This is a COMPLETE SERVICE REPAIR MANUAL for the: Yamaha DT175 DT175D DT 175 1992. will work with similar years and models Other specific year manuals for this model below. Free Downloads; Categories Agriculture; Business and Industrial; Cars; Construction. 6406 Downloads Details. 10 thoughts on 'Yamaha DT Owners Manuals' Kevin Crosson says: January 6, 2015 at 4:49 pm Thank you for the free copy of the Yamaha 1980 DT-125 Owners Manual. My son and I recently bought a 1980 DT-125 but it did not come with a manual. This is very helpful, thanks again. Download Yamaha DT175 DT175D DT 175 92 Service Repair Workshop Manual. YAMAHA DT175A DT175B Parts Manual Catalog Download 1974-1975. 1992-2002 YAMAHA DT175 Full Service Repair Manual INSTANT Download. Downloading; PDF Files; ISO Format; RAR / 7z Format; ZIP Files; OVA Files; Free Downloads; Categories Agriculture; Business. Yamaha Dt175 Workshop Manual: 20 assigned downloads, like Yamaha DT175 DT175D Workshop Service Repair Manual Download from instantmanuals. Empty; Home / Catalog / yamaha dt175 workshop manual. Merchants on tradebit get a free subdomain with their account - fully customizable Sign up. Download Yamaha Dt175 Dt175d Dt 175.
On-battery Waveshape
Stepped Sine Wave
Maximum Load
1000 VA - 600 W 1500 VA - 865 W
Typical Recharge Time
8 Hours
Operating Temperature
32
o
to 104
o
F
0
o
to 40
o
C
Storage Temperature
23
o
to 113
o
F
-5
o
to 45
o
C
Operating / Storage Relative Humidity
0 to 95% non-condensing
Size (H x W x D)
14.6 x 3.4 x 13.1 inch
37.1 x 8.6 x 33.3 cm
Weight
1000 VA 22 lbs (10 kg)
1500 VA 25 lbs (11 kg)
Samsung scx 4600 user manual pdf. This product detection tool installs software on your Microsoft Windows device that allows HP to detect and gather data about your HP and Compaq products to provide quick access to support information and solutions. Technical data is gathered for the products supported by this tool and is used to identify products, provide relevant solutions and automatically update this tool, to improve our products, solutions, services, and your experience as our customer.Note: This tool applies to Microsoft Windows PC's only.
Shipping Weight
1000 VA 23 lbs (11 kg)
1500 VA 26 lbs (12 kg)
EMI Classification
FCC / DOC Class B Certified
On Battery Run-Time
See http://www.apc.com/product
TROUBLESHOOTING
Mar 31, 2016 Dear Internet Archive Supporter, I ask only once a year: please help the Internet Archive today. Right now, we have a 2-to-1 Matching Gift Campaign, so you can triple your impact! Simcity 2000 manual download. SimCity 2000 Manual, PC - Special Edition (pdf):: SimCity 2000 (SC2K) is a simulation/city building video game and the second installment in the SimCity series. In SimCity 2000 the view was now dimetric instead of overhead, land could have different elevations, and underground layers were introduced for water pipes and subways. New types of facilities include prisons, schools, libraries.
Problem
Possible Cause
Corrective Action
Back-UPS will not switch on.
Back-UPS not connected to AC power source.
Ensure the Back-UPS is securely connected to an AC outlet.
Back-UPS circuit breaker 'tripped'.
Disconnect non-essential equipment from the Back-UPS. Reset
(push in) the rear panel circuit breaker. Switch on the Back-UPS
and plug in devices one at a time. If the circuit breaker trips
again, disconnect the device that caused the breaker to trip.
Utility input voltage quality is out of range.
Consider adjusting the transfer voltage and sensitivity. See
Transfer Voltage and Sensitivity Adjustment.
Back-UPS does not power
essential equipment during an
outage.
Equipment plugged into a Surge Only outlet.
Unplug device from 'Surge Only' outlet and move to a 'Battery
Backup' outlet.
Back-UPS operates on battery
although utility power exists.
Back-UPS circuit breaker 'tripped'.
Disconnect non-essential equipment from the Back-UPS. Reset
(push in) the rear panel circuit breaker. Switch the Back-UPS on
and plug equipment in one-at-a-time. If the circuit breaker trips
again, disconnect the device that caused the breaker to trip.
Utility input voltage quality is out of range.
Consider adjusting the transfer voltage and sensitivity. See
Transfer Voltage and Sensitivity Adjustment.
Back-UPS does not provide
expected backup time.
Back-UPS is heavily loaded.
Unplug non-essential equipment (printers, scanners, etc) from
the Battery Backup outlets and plug into 'Surge Only' outlets.
Back-UPS battery cartridge is discharged due to
recent power outage and has not had time to
recharge.
Charge the battery cartridge for 8 hours. Back-UPS runtime is
reduced until the battery cartridge is fully charged.
Battery has reached the end of its life.
Replace battery cartridge (see Order Replacement Battery
Cartridge).
Red Replace Battery indicator is
flashing. Green On Line indicator
is on.
Internal battery cartridge is not connected.
Connect battery cartridge (see Connect Battery Cartridge).
Red Replace Battery indicator is
on.
Battery has reached the end of its life.
Replace the battery cartridge (see OrderReplacement Battery
Cartridge).
Red Overload indicator is on or
flashing.
Connected equipment is drawing more power than
the Back-UPS can provide.
Move one or more equipment power plugs from Battery Backup
outlets to Surge Only outlets.
Green On Line indicator is on and
all other front panel indicators are
flashing.
Internal UPS fault.
Contact APC Technical Support (see Contact Information).
Battery
Cartridge
REPLACE BATTERY CARTRIDGE
ORDER REPLACEMENT BATTERY CARTRIDGE
The battery cartridge typically lasts 3-6 years, shorter if subjected to frequent outages or elevated temperatures. Order part number RBC33.
Please recycle spent battery cartridges.
990-2163A Copyright © 2007 American Power Conversion All rights reserved.
APC and Back-UPS are registered trademarks of American Power Conversion.
All other trademarks are the property of their respective owners.
SERVICE
If the Back-UPS arrived damaged, notify the carrier.
If the Back-UPS requires service, do not return it to the dealer. The following
steps should be taken:
1.
Consult the Troubleshooting section to eliminate common problems.
2.
Apc Back Ups 500 Manual
If the problem persists, go to http://www.apc.com/support/.
3.
If the problem still persists, contact APC Technical Support.
• Have the Back-UPS model number, serial number and date of purchase
available. Be prepared to troubleshoot the problem with an APC Technical
Support representative. If this is not successful, APC will issue a Return
Merchandise Authorization (RMA) number and a shipping address.
CONTACT INFORMATION
Technical Support
http://www.apc.com/support
Internet
http://www.apc.com
USA / Canada
1.800.800.4272
Mexico
292.0253 / 292.0255
Brazil
0800.12.72.1
Worldwide
+1.401.789.5735
LIMITED WARRANTY
The standard warranty is two (2) years from the date of purchase. APC's standard
procedure is to replace the original unit with a factory reconditioned unit. Customers
who must have the original unit back due to the assignment of asset tags and set
depreciation schedules must declare such a need at first contact with an APC Technical
Support representative. APC will ship the replacement unit once the defective unit has
been received by the repair department, or cross-ship upon the receipt of a valid credit
card number. The customer pays for shipping the unit to APC. APC pays ground
freight transportation costs to ship the replacement unit to the customer.
In situations where the Back-UPS or connected equipment appears too sensitive to
input voltage, it may be necessary to adjust the transfer voltage. This is a simple task
requiring use of the front panel pushbutton. To adjust the transfer voltage, proceed as
follows:
1. Plug the Back-UPS into the utility power source. The Back-UPS will be in a
Standby Mode (no indicators lit).
2. Press the front panel pushbutton fully inward for 10 seconds. All indicators on the
Back-UPS will flash to acknowledge going into Programming Mode.
3. The Back-UPS will then indicate its current Sensitivity Setting, as shown in the
following table.
4. To select the Low Sensitivity setting, press the pushbutton until the yellow
indicator is flashing.
5. To select the Medium Sensitivity setting, press the pushbutton until the yellow
and red indicators (second and third from the top) are flashing.
6. To select the High Sensitivity setting, press the pushbutton until yellow and both
Samsung printer clx 3175fn user manual. If the machine does not operate properly after instructions have been followed. If the machinSummary of the content on the page No. If the machine has been dropped, or the cabinet appears damaged. 7OZONE SAFETY During normal operation, this machine produces ozone.
red indicators (bottom three) are flashing.
7. To exit without changing the Sensitivity Setting, press the pushbutton until the
green indicator is flashing.
8. Once in Programming Mode, if the pushbutton is not pressed within 5 seconds,
the Back-UPS will exit Programming Mode; all indicators will extinguish.
Indicators
Flashing
Sensitivity
Setting
Input Voltage
Range
(for utility
operation)
RS Models
Input Voltage
Range
(for utility
operation)
XS Models
Use When
1
(yellow)
Low
78 - 150 Vac
78 - 142 Vac
Input voltage is
extremely low or high.
Not recommended for
computer loads.
2
(yellow,
and red)
Medium
(factory
default)
83 - 147 Vac
83 - 139 Vac
Back-UPS frequently
goes On Battery.
3
(yellow,
red, and
red)
High
88 - 144 Vac
88 - 136 Vac
Connected equipment is
sensitive to voltage
fluctuations .
TRANSFER VOLTAGE AND SENSITIVITY
ADJUSTMENT
Notice: This device complies with part 68 and 15 of the FCC rules.Operation is subject
to the following two conditions: (1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may
cause undesired operation.
On the bottom of this equipment is a label that contains, among other information, the
FCC registration number and ringer equivalence number (REN) for this equipment. If
requested, this information must be provided to the telephone company.
Back-UPS NS 600
User's Guide
1
2
3
Connect Battery
Equipment
Power On and
Install Software
990-2437A Copyright © 2007 American Power Conversion Corp.
All other trademarks are property of their respective owners.
Surge Protection
These outlets provide full-time protection from surges even if the
Back-UPS NS is switched OFF. Plug your printer, fax machine,
scanner, or other peripherals that do not need battery power into
these outlets.
Battery Back-up plus Surge Protection
These outlets are powered whenever the Back-UPS NS is
switched ON. During a power outage or other utility problems
(brownouts, over-voltages), these outlets will be powered for a
limited time by the Back-UPS NS. Plug your computer,
monitor, CD-ROM drive and one other data-sensitive device
such as an external disk or tape drive, or Home Phoneline
Networking Association (HPNA) device into these outlets.
Press the ON/OFF switch to power the unit
ON.
A single short beep and the green 'Power'
indicator confirms the Back-UPS NS is on and
ready to provide protection.
The Back-UPS NS should charge for at least 16
hours to ensure sufficient runtime. The unit is
being charged whenever it is connected to utility
power, whether the unit is turned ON or OFF.
If the red Building Wiring Fault indicator (located
on the end near the power cord) is lit, your
building wiring presents a shock hazard that
should be corrected by a qualified electrician.
Install the PowerChute
®
Personal
Edition
software
Place the PowerChute Personal Edition CD-
ROM into your computer and follow the
installation instructions on the screen.
w
w
w.apc.com
®
APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.
Status
Visual Indicators
Audible Indicators
Alarm Terminates
When
On Line - UPS is supplying conditioned
utility power to the load.
Power LED - ON
None
n/a
On Battery - UPS is supplying battery
power to the load connected to the
Battery outlets.
Apc Ups 600 Battery
Power LED - ON
(off during beep)
Beeping 4 times
every 30 seconds
UPS transfers back to
On Line operation, or
when UPS is turned
off.
Low Battery Warning - UPS is supplying
battery power to the load connected to
the Battery outlets and the battery is near
exhaustion.
Power LED - Flashing
Rapid beeping (half-
second intervals)
UPS transfers back to
On Line operation, or
when UPS is turned
off.
Replace Battery - Battery needs to be
checked and/or replaced, or battery is not
connected.
Power LED - Flashing
Constant tone
UPS turned off with
the power switch.
Overload Shutdown - During On Battery
operation a battery power supplied outlet
overload was detected.
Power LED - OFF
Constant tone
UPS turned off with
the power switch.
Sleep Mode - During On Battery
operation the battery power has been
completely exhausted and the UPS is
waiting for utility power to return to
normal.
Power LED - OFF
Beeping once every
4 seconds
Utility power is
restored, or if utility
power is not restored
within 32 seconds, or
the UPS is turned off.
Building Wiring Fault - Your building
wiring presents a shock hazard that
should be corrected by a licensed
electrician.
Building Wiring Fault
LED (red) - ON
None
UPS is unplugged, or
plugged into a
properly wired outlet.
Status Indicators
![Apc Ups Rs 600 User Manual Apc Ups Rs 600 User Manual](http://www.manualsdir.com/manuals/720731/2/apc-xs-1500-page2.png)
Power
Circuit
Breaker
AC Line
Apc Back Ups 700 Manual
Cord
Building Wiring
Fault Indicator
UPS Power
Indicator
Power
Switch
®
See the Troubleshooting section for additional assistance.
For safety, the Back-UPS NS is shipped with one battery wire disconnected. The UPS will not operate until the wire is connected to the touch-safe
battery terminal. NOTE: Small sparks may occur during battery connection. This is normal.
Turn the Back-UPS NS over and press in the
two release tabs. Slide the plastic battery
cover off the unit.
Insert the battery back into the compartment.
Slide the plastic battery cover in place until the
two tabs lock into place.
Back Ups 600 Apc
Connect the battery wire firmly to
the battery terminal.
1
2
3
Plastic Battery
Cover
Release Tabs
Battery Wire
Battery Terminal
Connect
Connect Modem / Phone / DSL / Fax / HPNA to Surge Protection
The Back-UPS protects a single line (2-wire) phone (including Digital Subscriber Line -
DSL), Home Phoneline Networking Association (HPNA) type equipment, modem, or
fax machines from surges when connected through the UPS as shown below.
Place the Back-UPS NS to avoid:
- Direct sunlight
- Excessive heat
- Excessive humidity or contact with fluids
Plug the Back-UPS NS power cord directly into a wall outlet; not a surge
protector or power strip.
Connect Computer Cable
The supplied cable and software provide automatic file saving and shutdown of the
operating system in the case of a sustained power outage.
Connect the cable to the Data Port of the Back-UPS NS. Connect the other end of the
cable to the USB port on your computer. The software will automatically find the USB
Port of your computer.
DSL / MODEM /
WALL
TO COMPUTER USB PORT
FROM WALL JACK
DATALINE OUTPUT TO DSL,
MODEM, PHONE,
Messenger Lite is an official client developed by Facebook for its well-known instant messaging service. Facebook lite apk free download for android mobile.
OUTLET
Apc 1500 Ups Manual
DATA PORT
FAX
Power
Battery Backup plus Surge Protection
Surge Protection
The Back-UPS NS indicates operating status
using a combination of visual and audible
indicators.